Chat with us, powered by LiveChat

Cast Nylon – Black
(Tecast T MO)

Main features

  • good wear properties
  • high toughness
  • resistant to many oils, greases and fuels
  • good damping
  • good slide and wear properties
  • high strength

To view Cast Nylon – Black
(Tecast T MO)
mechanical properties, thermal properties, electrical properties, other properties, specifications or shapes & sizes please click on the tabs below.


Colour:
Colour Code
This product appears in:


Rounds (mm)
50
55
60
65
70
75
80
85
90
95
100
110
120
125
130
135
140
150
160
170
180
190
200
210
220
230
250
280
300
320
350
370
400
150
500
Plate (mm)
10
12
16
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
120
130

Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.

Chemical Designation

PA 6 C (Cast polyamide 6)

Colour

black opaque

Density

1.15 g/cm3

Data generated directly after machining
(standard climate Germany)


Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.

Value Unit Parameter Norm
Tensile strength 82 MPa 50mm/min DIN EN ISO 527-2
Tensile strength at yield 80 MPa 50mm/min DIN EN ISO 527-2
Elongation at yield 4 % 50mm/min DIN EN ISO 527-2
Elongation at break 55 % 50mm/min DIN EN ISO 527-2
Flexural strength 102 MPa 2mm/min, 10 N DIN EN ISO 178 1)
Modulus of elasticity
(flexural test)
3000 MPa 2mm/min, 10 N DIN EN ISO 178
Compression strength MPa 1% / 2% / 5% EN ISO 604 2)
Compression modulus 2800 MPa 5mm/min, 10 N EN ISO 604 3)
Impact strength (Charpy) n.b. kJ/m2 max. 7,5J DIN EN ISO 179-1eU 4)
Notched impact strength (Charpy) 4 kJ/m2 max. 7,5J DIN EN ISO 179-1eA
Ball indentation hardness 170 MPa ISO 2039-1 5)
Modulus of elasticity
(tensile test)
3200 MPa 1mm/min DIN EN ISO 527-2 6)

(1) For tensile test: specimen type 1b
(2) For flexural test: support span 64mm, norm specimen.
(3) Specimen 10x10x10mm
(4) Specimen 10x10x50mm, modulus range between 0.5 and 1% compression.
(5) For Charpy test: support span 64mm, norm specimen. n.b. = not broken
(6) Specimen in 4mm thickness


Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.

Value Unit Parameter Norm
Melting temperature 217 C DIN EN ISO 11357
Service temperature 170 C short term NN 1)
Service temperature 100 C long term NN
Thermal expansion (CLTE) 11 10-5*1/K 23-60°C, long. DIN EN ISO 11359-1;2
Thermal expansion (CLTE) 11 10-5*1/K 23-100°C, long. DIN EN ISO 11359-1;2
Glass transition temperature 43 C DIN EN ISO 11357 2)
Specific heat 1.6 J/(g*K) ISO 22007-4:2008
Thermal conductivity 0.33 W/(k*m) ISO 22007-4:2008

(1) Found in public sources.
(2) Found in public sources. Individual testing regarding application conditions is mandatory.


Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.

Value Unit Parameter Norm
surface resistivity 1014 O DIN IEC 60093
volume resistivity 1014 O*cm DIN IEC 60093 1)

(1) Specimen in 20mm thickness
(2) Specimen in 1mm thickness


Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.

Value Unit Parameter Norm
Resistance to hot water/ bases (+) 1)
Flammability (UL94) HB corresponding to DIN IEC 60695-11-10; 2)
Resistance to weathering (+) NN
Water absorption 0.5 % 24h / 96h (23°C) DIN EN ISO 62 3)

(1) Ø ca. 50mm, h=13mm
(2) (+) limited resistance
(3) - poor resistance
(4) Corresponding means no listing at UL (yellow card). The information might be taken from resin, stock shape or estimation. Individual testing regarding application conditions is mandatory.


Our information and statements reflect the current state of our knowledge and shall inform about our products and their applications. They do not assure or guarantee chemical resistance, quality of products and their merchantability in a legally binding way. Our products are not defined for use in medical or dental implants. Existing commercial patents have to be observed. The corresponding values and information are no minimum or maximum values, but guideline values that can be used primarily for comparison purposes for material selection. These values are within the normal tolerance range of product properties and do not represent guaranteed property values. Therefore they shall not be used for specification purposes. Unless otherwise noted, these values were determined by tests at reference dimensions (typically rods with diameter 40-60 mm according to DIN EN 15860) on extruded and machined specimen. As the properties depend on the dimensions of the semifinished products and the orientation in the component (esp. in reinforced grades), the material may not be used without a separate testing under individual circumstances. The customer is solely responsible for the quality and suitability of products for the application and has to test usage and processing prior to use. Technical changes reserved.